Language Reference • Reference

Publication 1398-PM601A-EN-P — October 2000

WORDS

HLIMITS

Travel Limits Enabled Flag

System

Purpose

Set if travel limit inputs are enabled.

Syntax

variable = HLIMITS

variable

The variable may be a nonvolatile flag Bn, a volatile flag Fn, or
another system flag.

Remarks

See Also

DISLIM

Example

F4 = HLIMITS

IF HLIMITS = ON

HOFFS

Home Offset

Home

Purpose

Set the Home Offset. Home Offset specifies the distance from the encoder index, or
home switch if there is no index, to the home position. The sign specifies the direction
of the offset.

Syntax

HOFFS = value
variable =
HOFFS

value

The Home Offset is entered in user units. User units are defined
by the SCALE parameter. Value can be a constant, a nonvolatile
variable Gn, a volatile variable Vn, or a system variable.

variable

The variable can be a nonvolatile variable Gn, a volatile vari-
able Vn, or a system variable.

Remarks

The default home program finds the home position based on the home switch and/or
the encoder index. Once this position is found, an incremental move is made with a
distance of HOFFS. Home position (zero) is then defined. A detailed description of the
home program is in Appendix A.

Changes made to this variable by a program are only in effect while the program is
running. When the program ends it will return to the value stored in the Personality
Module. If no change is made to this variable by the program, the value in the Person-
ality Module is used. The value in the Personality Module is set in the Parameter
menu, Velocity/Accel dialog box.

See Also

DP, DH, Appendix A, System Programs

Example

HOFFS = 1.5

V2 = HOFFS