Enable / disable, Miscellaneous instruction summary, Tutorial – Rockwell Automation 1398-PDM-xxx IQ Master Version 3.2.4 for IA-2000 and IQ-5000 Positioning Drive Modules, IQ-55 User Manual

Page 191

Advertising
background image

Miscellaneous • Miscellaneous Instruction Summary

169

Publication 1398-PM601A-EN-P — October 2000

TUTORIAL

DH

;define current commanded position as zero

DP = 200

;define the current commanded position as 200

DP = 0

;this is equivalent to a DH

DP1 = 100

;define the encoder 1 position (POS1) as 100

These commands change the commanded position. The feedback position is also changed in such a way
as to maintain the same following error that was present before the instruction was executed.

Enable / Disable

The ENABLE and DISABLE commands are used to enable and disable motor torque. These commands
can be issued from three different sources: the application program, an assigned input, or a Host Lan-
guage Command. Any of the three sources can disable the ULTRA Plus or IQ at any time. The only
source that can re-enable the ULTRA Plus or IQ (without resetting the ULTRA Plus or IQ) is the source
that disabled the ULTRA Plus or IQ.

DISABLE

;Disable the motor

ENABLE

;Enable the motor

Miscellaneous Instruction Summary

The following is a summary of the miscellaneous commands discussed in this section. Refer to Part 5

Language Reference for more detailed information.

Name

Description

CONFIG = n

Select the ULTRA Plus or IQ configuration

DH

Define the current position as home

DISABLE

Disable the ULTRA Plus or IQ

DP = value

Redefine the current position

DP1 = value

Redefine Encoder1 position

DP2 = value

Redefine Encoder2 position

ENABLE

Enable the ULTRA Plus or IQ