XLOOPINDEX

X-Routine Loop Index

System

Purpose

The LOOP counter for the LOOP instruction used in the Xkey routine.

Syntax

XLOOPINDEX= value
variable
= XLOOPINDEX

value

Value can be a constant, a global variable Gn, a volatile variable
Vn, or another system variable.

variable

Variable can be a nonvolatile variable Gn, a volatile variable
Vn, or another system variable.

Remarks

Mark the end of a block of instructions to be repeated in a loop. The range of the loop
counter is 0 to 65535. If count is 0 the statements in the loop will not execute.

The LOOP statements cannot be used in Fkey or Scanned Event routines. If a subrou-
tine is called from a LOOP, the subroutine may not contain a LOOP.

The XNPGM = number statement can be used to simulate pressing an Xkey from
within a program.

See Also

LOOP, LOOPINDEX, REPEAT

Example

X1:

LOOP 3

V4 = XLOOPINDEX

PRINT V4

REPEAT

XEND

XNACTIVE

Xkey Routine Active

System

Purpose

Xkey active flag. This flag indicates when an Xkey on the Operator Terminal is
pressed.

Syntax

variable = XNACTIVE

variable

The variable may be a nonvolatile flag Bn, a volatile flag Fn, or
another system flag.

Remarks

ON indicates that and Xkey is pressed. OFF indicates there are no Xkeys pressed. The
XNPGM = number statement can be used to simulate pressing an Xkey from within a
program.

See Also

FNACTIVE, Xn, Operator Terminal

Example

WAIT XNACTIVE = OFF