System Program 8 - Set Feedrate

This prompts an operator to enter a new Feedrate percentage. The Operator Terminal screen and keypad
is used to READ the new value. The present value of Feedrate is displayed.

Program Listing

;Source File Name: SETFDR.QPS

;Version: 3.00

;Tested with IQMaster Version: 3.00

;Tested with IQ firmware Version: 3.00

;------------------------------ Description ------------------------------

;This is the default operator terminal function key program to

;set feedrate FDR.

;This program is saved as System Program #8 in standard personality modules.

;It may also be saved as any Function Key System Program (range is 1-24).

;The source is NOT saved in standard personality modules.

;

;This program prompts an operator to enter feedrate with the operator

;terminal keypad. The present value is displayed to allow pressing

;Enter to keep the present value.

;

;---------------------------- Variables used -----------------------------

;FNVAR1 special variable reserved for Function Key programs

;-------------------------------- Inputs ---------------------------------

;none

;-------------------------------- Outputs --------------------------------

;none

;---------------- Optional Accessories Required/Supported ----------------

;Operator Terminal - REQUIRED

;An operator enters the feedrate using the operator terminal keypad.

;----------------------------- Begin Program -----------------------------

TITLE "Set FDR"

PGMTYPE = FKEYPGM ;Set compiler options

DEBUG = OFF

CLR ;Clear screen

PRINT "Feedrate: %" ;Print header

FNVAR1 = FDR ;Get present value

READ 1,10 ,SHOW FNVAR1 ,6,2 (0,200) ;Read in new value. Note that the

; present value is displayed. Values

; from 0 to 200 with 2 decimal places

; of accuracy are allowed.

CLR ;Clear screen

FDR = FNVAR1 ;Set new feedrate

END