246

Language Reference • Reference

Publication 1398-PM601A-EN-P — October 2000

WORDS

PFE

Following Error, Peak

Position

Purpose

Peak following error in user units.

Syntax

variable = PFE

variable

The variable may be a nonvolatile variable Gn, a volatile vari-
able Vn, or a system variable.

Remarks

The following error is calculated every position loop update (2mS). If the present
value is greater than the previous peak the value is saved as the new peak. The magni-
tude of the peak is calculated based on an absolute value of following error. The value
is saved and reported as a signed number, however.

CLRPEAKS resets this value to zero.

See Also

FE, CLRPEAKS

Example

V1 = PFE

PGAIN

Proportional Gain, Velocity Loop

Gain

Purpose

Set the proportional gain for the velocity loop. The velocity loop proportional gain
may be changed at any time in the program.

Syntax

PGAIN = value
variable
= PGAIN

value

The value may be a nonvolatile variable Gn, a volatile variable
Vn, or a system variable.

variable

Variable may be a nonvolatile variable Gn, a volatile variable
Vn, or a system variable.

Remarks

Changes made to this variable by a program are only in effect while the program is
running. When the program ends it will return to the value stored in the Personality
Module. If no change is made to this variable by the program, the value in the Person-
ality Module is used. The value in the Personality Module is set in the Parameter
menu, Gains/Limits dialog box.

See Also

IGAIN, FGAIN

Example

PGAIN = 0.5

Advertising