Language Reference • Reference

Publication 1398-PM601A-EN-P — October 2000

WORDS

ATHOME

At Home Flag

Home

Purpose

When the flag is ON it indicates that the motor is within the In-Position window of the
zero position. ATHOME is used in Absolute mode only.

Syntax

variable = ATHOME

variable

The variable may be a nonvolatile flag Bn, a volatile flag Fn, or
another system flag.

Remarks

WINDOW, INPOSN

See Also

Example

IF ATHOME = ON O2 = ON

F1 = ATHOME

Bn

Nonvolatile User Flag

Variable

Purpose

Set a user flag ON or OFF with another flag or constant.

Syntax

Bn = ON/OFF/Fm/Bn
variable =
Bn

n, m

The number of the flag. n = 1, 2, 3, ..., 8 or m = 1, 2, 3, ..., 64.

variable

Variable may be a nonvolatile flag Bn, a volatile flag Fn, or
another system flag.

Remarks

The changes made to Bn remain in effect even after the power is turned OFF. Changes
made to Bn by one program will be seen by other programs.

TIP: Variables can be assigned names using the ASSIGN command and then refer-
enced by those names to make the program easier to read.

See Also

Gn, Fn, Vn

Example

B1 = ON

B2 = OFF

IF B1 = ON MOVD = 2

B3=F63