Language Reference • Reference

221

Publication 1398-PM601A-EN-P — October 2000

WORDS

action2

The action to be taken if the condition is FALSE. The action may
be any programming statement. Multiple statements may be
enclosed in curly braces {}.

Remarks

Only action1 or action2 will happen. It is impossible for both actions to take place.

See Also

WHILE, DO/WHILE

Example

IF POSN>5 O2 = ON ELSE 02 = OFF

IF F3 = ON JUMP BEGIN

IF (V1 <> 10) V1 = V1 + 1

IF I12 = ON CLEAR

IF F7 = OFF CALL SUB1

IF G1 < = 0 READ G1

IF I1 = ON

;IF input 1 on move 1 and turn on output 1

{

MOVD = 1

O1 = ON

}

ELSE

;Else move distance 2 and turn on output 2

{

MOVD = 2

O2 = ON

}

IGAIN

Integral Gain, Velocity Loop

Gain

Purpose

Set the integral gain for the velocity regulator. IGAIN can be changed at any time in
the program.

Syntax

IGAIN = value
variable =
IGAIN

value

The value can be a constant, a nonvolatile variable Gn, a vola-
tile variable Vn, or a system variable.

variable

The variable may be a nonvolatile variable Gn, a volatile vari-
able Vn, or a system variable.

Remarks

Changes made to this variable by a program are only in effect while the program is
running. When the program ends it will return to the value stored in the Personality
Module. If no change is made to this variable by the program, the value in the Person-
ality Module is used. The value in the Personality Module is set in the Parameter
menu, Gains/Limits dialog box.

See Also

PGAIN, FGAIN

Example

IGAIN = 0

IG = V10