Operator Terminal Commands • Commands

317

Publication 1398-PM601A-EN-P — October 2000

HOST M

O

DE

Operator Terminal Commands

Commands

The following commands are available to directly access the Operator Terminal for diagnostics or simu-
lation purposes.

FNPGM fn#

This command may be used to start execution of an Fkey program without forcing the operator to press
a key on the operator terminal.

The “fn#” must be in the range 1..24 and will only be meaningful if the specified program exists in the
System Directory. A menu does not need to be present on the bottom line of the Operator Terminal to
use this command.

OTADDR address

Sets the address when using the Operator Terminal Multidrop mode. Valid range is 0-9.

OTCLS

Clears the Operator Terminal Screen. This action is taken only if the Operator Terminal is inactive and
is normally used only by diagnostics.

OTCP

Returns the current position of the cursor and clears the new cursor position flag of OTS. The cursor is
only visible when the Operator Terminal is doing input. The position is returned in the format:

Row, Col (Note: Row and Col are zero based)

OTFILL byte

This command may be used to fill the Operator Terminal screen with an ASCII character. It is normally
used only in diagnostics mode. The request will only be carried out if the Operator Terminal is inactive
and the character byte is in the range 0x20..0x7f.