I/O Expansion • Using the Additional I/O

Publication 1398-PM601A-EN-P — October 2000

I/O

I/O Expansion

Additional I/O may be added with either an I/O Expansion Card or a Memory and I/O Expansion Card.
These boards add the following input and output capabilities to the ULTRA Plus or IQ.

32 TTL Inputs

16 TTL Outputs

4 twelve bit Analog inputs (only with the Memory and I/O Expansion Card)

For detailed specifications and installation instructions refer to the appropriate ULTRA Plus or IQ-
Series Installation Manual
(1398-5.1, Part Number 0013-1027-004 or Part Number 0013-1022-004).

Using the Additional I/O

Inputs

The additional inputs can be used just like the inputs on the base ULTRA Plus or IQ. The expansion I/O
inputs are numbered I17 through I48.

Outputs

The additional outputs can be used just like the outputs on the base ULTRA Plus or IQ. The expansion I/
O outputs are numbered O9 through O24.

Analog Inputs

The additional analog inputs can be used exactly like the analog inputs on the base ULTRA Plus or IQ.
The expansion I/O analog inputs are referenced as ADC2, ADC3, ADC4 and ADC5. (Feedrate may
only be assigned to ADC1)