VHDL Master BFM
get_read_data_cycle()

April 2014

get_read_data_cycle()

This blocking procedure waits until the read data channel RVALID signal has been asserted.

Example

// Wait for the RVALID signal to be asserted.
bfm.get_read_data_cycle(bfm_index, axi4_tr_if_0(bfm_index));

Prototype

procedure get_read_data_cycle
(

bfm_id : in integer;
path_id : in axi4_adv_path_t; --optional
signal tr_if : inout axi4_vhd_if_struct_t

);

Arguments

bfm_id

BFM identifier. Refer to

Overloaded Procedure Common Arguments

on page 151 for more details.

path_id

(Optional) Parallel process path identifier:

AXI4_PATH_5
AXI4_PATH_6
AXI4_PATH_7

Refer to

Overloaded Procedure Common Arguments

” on page 151 for

more details.

tr_if

Transaction signal interface. Refer to

Overloaded Procedure Common

Arguments

” on page 151 for more details.

Returns

None