Mentor Verification IP AE AXI4-Lite User Guide, V10.3

304

VHDL Monitor BFM
set_write_data_mode()

April 2014

set_write_data_mode()

This nonblocking procedure sets the write_data_mode field for a transaction that is uniquely
identified by the transaction_id field previously created by the

create_monitor_transaction()

procedure.

Note

You do not normally use this procedure in a monitor test program.

Prototype

set_write_data_mode
(

write_data_mode: in integer;
transaction_id : in integer;
bfm_id : in integer;
path_id : in axi4_path_t; --optional
signal tr_if : inout axi4_vhd_if_struct_t

);

Arguments

write_data_mode

Write data mode:

AXI4_DATA_AFTER_ADDRESS (default);
AXI4_DATA_WITH_ADDRESS;

transaction_id

Transaction identifier. Refer to

Overloaded Procedure Common

Arguments

” on page 151 for more details.

bfm_id

BFM identifier. Refer to

Overloaded Procedure Common Arguments

on page 151 for more details.

path_id

(Optional) Parallel process path identifier:

AXI4_PATH_0
AXI4_PATH_1
AXI4_PATH_2
AXI4_PATH_3
AXI4_PATH_4

Refer to

Overloaded Procedure Common Arguments

” on page 151 for

more details.

tr_if

Transaction signal interface. Refer to

Overloaded Procedure Common

Arguments

” on page 151 for more details.

Returns

None