SystemVerilog Master BFM
get_config()
Mentor Verification IP AE AXI4-Lite User Guide, V10.3
45
April 2014
get_config()
This function gets the configuration of the master BFM.
Example
get_config(AXI4_CONFIG_MAX_TRANSACTION_TIME_FACTOR);
Prototype
function void get_config
(
input axi4_config_e config_name,
);
Arguments
config_name
Configuration name:
AXI4_CONFIG_SETUP_TIME
AXI4_CONFIG_HOLD_TIME
AXI4_CONFIG_MAX_TRANSACTION_TIME_FACTOR
AXI4_CONFIG_AXI4LITE_axi4
AXI4_CONFIG_ENABLE_ALL_ASSERTIONS
AXI4_CONFIG_ENABLE_ASSERTION
AXI4_CONFIG_MAX_LATENCY_AWVALID_ASSERTION_
TO_AWREADY
AXI4_CONFIG_MAX_LATENCY_ARVALID_ASSERTION_
TO_ARREADY
AXI4_CONFIG_MAX_LATENCY_RVALID_ASSERTION_
TO_RREADY
AXI4_CONFIG_MAX_LATENCY_BVALID_ASSERTION_
TO_BREADY
AXI4_CONFIG_MAX_LATENCY_WVALID_ASSERTION_
TO_WREADY
AXI4_CONFIG_SLAVE_START_ADDR
AXI4_CONFIG_SLAVE_END_ADDR
Returns
config_val
See “
” on page 40 for descriptions and valid
values.