SECTION 2 - OPERATION

2-63

NOTE: The cold start button, 1, does not need to be

held in during operation.

NOTE: A monitoring device prevents the heater from

working unless both the engine coolant and the

intercooler temperature are below 15

°

C (59

°

F).

NOTE: The preheat cycle will be deactivated if the

battery voltage drops below 9 Volts.

6. When the cold start light, 2, turns off, turn the key

switch to the “START” position.

7. If the engine does not start after 20 seconds of

cranking, turn the key switch to the ”OFF”

position, allow the starter to cool for two minutes,

then repeat the procedure starting at step 4.

8. When the engine starts (approximately 800

RPM) release the key switch. Check that all

warning lights extinguish and gauge readings

are normal.

NOTE: During cranking, the air inlet heater is off until

the engine achieves 400 RPM. At 400 RPM, the air

inlet heater will heat again in automatic or manual

mode, and remain on until the coolant and the

intercooler temperature are above 15

°

C (59

°

F). The

heater may automatically turn on and off for up to 20

minutes after the engine has started.

NOTE: During the post heat cycle, the heater will be

deactivated if the battery voltage drops below 10.5

Volts.