SECTION 4 - TROUBLESHOOTING

4-10

CAB

PROBLEM

POSSIBLE CAUSE

CORRECTION

Dust enters the cab

Improper

seal

around

filter

element

Plugged filter

Defective filter

Excessive air leak(s)

Check seal condition

Clean or replace filter

Replace filter

Seal air leak(s)

Pressurizer air flow low

Plugged

filter

or

plugged

recirculation filter

Heater core or evaporator core

plugged

Clean or replace filter(s)

See your authorized dealer

Air conditioner does not cool

Condenser plugged

Low refrigerant

Belt slipping or damaged

Heater control turned on

Clean radiator, oil cooler, and

condenser

Check sight glass for bubbles.

Contact your authorized dealer.

Check automatic belt tensioner

and belt condition

Turn temperature control knob fully

counterclockwise for maximum

cooling