SECTION 2 - OPERATION

2-80

To turn off the remote electro-hydraulics, depress the

engagement switch knob as shown.

IMPORTANT: The remote valve electro-hydraulic

engagement switch is provided as an isolator stop

switch. It can be used to immediately stop operation

of the rear remote hydraulics by quickly depressing

the knob. The stop switch only controls the remote

valves and has no effect on the three point hitch link

operation, thereby isolating operation of the rear

remote hydraulics from the three point hitch link

operation.

1

2

119

MANUAL-PROGRAMABLE OPERATION

SWITCHES

Rocker switch, 1, is used to select either the manual

or programmed operation for each of the remote

control switches.

Manual Operation

Manual operation is provided primarily for the

operation of continuous flow applications, such as

hydraulic motors. To operate the remote electro-hy-

dualic valves in manual mode, depress the top of

rocker switch, 1, as shown. In the manual mode, the

control switch, 2, can be operated in the four

positions, neutral, extend, retract and float. When the

control switch is left in either the extend, retract or

float positions the control switch WILL NOT

automatically return to the neutral position and shut

the flow of oil off to the rear remotes regardless if the

system reaches maximum pressure. The control

switch must MANUALLY be returned to neutral.

There is no automatic return to neutral. This allows

for efficient operation of motors without nuisance

shut downs when the remote valve in advertantly

returns to neutral. When operating hydraulic motors

it is important to always use the RETRACT position

to activate the motor and the FLOAT position to stop

the motor. Using the float position to stop the motor

allows the motor to come to a gradual stop

preventing any damage to the motor itself.

IMPORTANT: Never use the neutral position from

the extend or retract position to stop a hydraulic

motor. Sudden hydraulic lock up of the system can

cause extensive damage to the motor.

IMPORTANT: Do not operate the control switches in

the manual mode when operating remote cylinders.

When the cylinder has reached the end of its stroke

the control switch will not return to neutral and the

hydraulic system relief valve will be activated. This

will overheat the oil and may lead to failure of the

hydraulic and driveline components.