SECTION 3 - LUBRICATION AND MAINTENANCE

3-58

EVERY 2400 HOURS OR 24 MONTHS (WHICHEVER OCCURS FIRST)

3. Open the drain plug, 1, on the radiator and drain

all the coolant into a suitable container. Dispose

of the coolant properly. The system holds 26.4

liters (7 U.S. gallons).

WARNING

Coolant should be kept off the skin. Adhere to the

precautions outlined on the antifreeze container.

99

4. Remove the drain plug, 1, from the left rear of the

engine block. Drain all the coolant into a suitable

container. Dispose of the coolant properly.

100

5. Remove the radiator cap,1, to increase the

drainage rate.