Buhler 2180 User Manual

Page 127

Advertising
background image

SECTION 2 - OPERATION

2-81

Programmable Operation

Programmable operation is provided primarily for

operation of hydraulic cylinders. This feature allows

the operator to program a time delay between when

the control switches are activated and when they will

automatically return to neutral. To operate the remote

electro-hydualic valves in programmed mode,

depress the bottom of rocker switch, 1, as shown.

When the bottom of the switch is depressed, light, 2,

in the switch will begin to flash. This is an indication

to the operator that a timed sequence must be

programmed into the electro-hydraulic controler. The

light will continue to flash for ten second to allow the

operator time to begin the programming sequence.

If a program is not started within this ten second

period, the controller will not accept any sequence

and the remote control switch, 3, will not remain

latched in either the extend or retract positions.

1

3

2

121

To program the electro-hydraulic’s, first insure that

the cylinder hydraulic hoses are properly connected

to the appropriate rear remote valve. Start the tractor

engine and insure the electro-hydraulic engagement

switch is up/on. Set the tractor engine RPM’s at the

normal operating speed in which the cylinder is to be

operated. This is important as the programming of

the control switches is based on a time interval to

correspond to the time it takes the cylinder ram to

extend as well as retract. Any change in engine rpm

will have and effect on hydraulic flow (GPM) and

therefore the time it takes the cylinder to extend and

retract. The control switch timed program always

remains the same regardless of oil flow (GPM) until

reprogrammed. Therefore consistent operation is

required for the system to operate correctly. Using

the corresponding color coded programming switch,

1, depress the bottom of the switch so light, 2, begins

to flash. While the light is flashing use control switch,

3, to extend the cylinder. As soon as the control

switch is activated the programming light will go on

solid. Hold the switch until the cylinder is extended to

the desired position and then return the switch to the

neutral position. When the switch is returned to the

neutral position the programming light will once

again begin to flash indicating that the retract phase

of the cycle needs to be programmed. Next use

control switch, 3, to retract the cylinder. As soon as

the control switch is activated the programming light

will go on solid. Hold the switch until the cylinder is

retracted to the desired position and then return the

switch to the neutral position. After the second phase

has been completed the programming light will go

out indicating that the programming has been

memorized. The control switch timed operation is

now programmed for the extend and retract

operation of the cylinder.

Repeat the above sequence to program the

remaining control switches.

Programming of the control switch can be preformed

in either sequence, extend/retract, retract/extend or

one sequence only, extend or retract. The program

for the individual control switch, 3, will remain the

same even when the engine is stopped and the

ignition switch is in the off position, as long as the

programming switch, 1, remains in the program

position as shown. The maximum allowable time limit

for any programmed timed operation is two minutes.

Programming the control switches with the engine

and hydraulic flow off is possible however accuracy

of actual operation will be marginal. Whenever a

hydraulic application is changed, the control

switches should be reprogrammed to suit the new

operation.

When operating in the timed programmed mode,

feathering of the hydraulic flow is possible by moving

the control switch variably any where between the

neutral position and the fully opened position. The

timed operation sequence only beings once the

control switch has been locked in the fully opened

position.

Should the control switch be moved to the float

position no timed program is possible and the control

switch must be returned back to neutral manually.

Advertising