SECTION 2 - OPERATION

2-85

HYDRAULIC MOTOR APPLICATION

1. Use hydraulic motors designed for Open Center

or Pressure/Flow Load Compensating hydraulic

systems only. Do Not use a hydraulic motor

designed for closed center hydraulic systems

unless it is adapted for use by removing the inlet

restrictor.

2. Rating: Hydraulic motors up to 1.26 L/SEC (20.0

GPM US) @ 15.50 MPa (2250 PSI) can be used.

3. Be sure the hydraulic motor does not have

restrictors in the ports or fittings.

4. Hydraulic motors less than 0.63 L/SEC (10 GPM

US) may be equipped with 12.7 mm (1/2″) ID

hoses and standard (ASAE/SAE/ISO) couplers.

5. Hydraulic motors greater than 0.63 L/SEC (10

GPM US) should be connected with (3/4″ ) hoses

and (ASAE/SAE/ISO) couplers to prevent

excessive restriction and heat generation.

6. It is recommended that the low pressure return

line kit (described earlier in this section) be

installed. The use of the low-pressure return

circuit will reduce back pressure in the remote

hydraulic return line which will result in more

efficient hydraulic motor operation. The low-

pressure return circuit can also be used in

applications where low return oil pressure is

desired to improve implement operation such as

with orbit motor case drain lines, or implement

mounted hydraulic control valves.

OPERATING REMOTE EQUIPMENT

SIMULTANEOUSLY OR REMOTE

EQUIPMENT AND HYDRAULIC LIFT

SIMULTANEOUSLY

NOTE: Hydraulic pump output varies with engine

speed. Oil flow will be relatively constant in the

remote control valve circuits if the flow control is used

to provide reduced oil flow, thus providing constant

operating speed for hydraulic motors, etc. even if

engine speed varies. Maintain the engine speed

above the minimum required for simultaneous

operation of all required circuits and vary ground

speed by selection of the appropriate gear.

If operating two or more remote control valves

simultaneously or remote valves and hydraulic lift, all

the flow control knobs should be adjusted to provide

a partial flow. Otherwise, all the available flow may be

directed to the full flow circuit when the pressure in

that circuit is less than that of the other circuits in use.

BLEEDING REMOTE CYLINDERS

When connecting a cylinder with trapped air, i.e., a

new cylinder, one that has been out of service or one

that has had the hoses disconnected, it will be

necessary to bleed the cylinder to remove the air.

With the hoses connected to the remote control valve

couplers at the rear of the tractor, position the

cylinder with the hose end uppermost and extend

and retract the cylinder seven or eight times using the

remote control switch. Check the rear axle oil level

before and after operating the remote cylinder.

POWER BEYOND APPLICATIONS

All BVI Genesis tractors are “Power Beyond” ready

in that another closed center load sensing valve may

be incorporated with the Genesis closed center load

sensing hydraulic system.

The pressure for the Power Beyond is obtained from

the (1”) ORB port, 1, (1 5/16--12 thread) on the top

cover of the valve. If the tractor is equipped with

HydraFlow Plus, replace the elbow fitting located at

port 1 with a tee fitting to access the supply pressure.

The sense line is attached to the (1/4”) ORB port, 2,

(7/16 -- 20 thread) located on the rear face of the

valve end cover.

The return line from the external valve would go to the

low pressure return port on the HPL cover. This is

explained earlier in this section.