SECTION 3 - LUBRICATION AND MAINTENANCE

3-60

EVERY 2400 HOURS OR 24 MONTHS (WHICHEVER OCCURS FIRST)

19. Fill the coolant recovery tank, 1, to the lowest

mark, 2.

20. Start the engine and run it until normal operating

temperature is reached.

NOTE: The coolant level will drop as coolant is

pumped around the system.

21. Stop the engine and allow the coolant to cool.
22. Remove the radiator cap and add coolant to the

radiator to bring the coolant level to the bottom of

the filler neck. Install the radiator cap.

23. Add coolant to the recovery tank as required to

bring the level to the cold mark.

NOTE: If the engine is not going to be operated

immediately following the coolant and filter change,

run the engine for one hour to ensure that the

chemical conditioner within the filter is dispersed into

the cooling system.

Antifreeze Specification: See Specifications
Clean Water Specification (Maximum):

Total Hardness

300 parts per million

Chlorides

100 parts per million

Sulfates

100 parts per million

Coolant Capacity: 26.4 liters (7 U.S. gallons)

103