SECTION 2 - OPERATION

2-32

Setting Implement Width

In order that the modules may calculate the work

done, the working width of the implement in use must

be entered into the memory.

Implement width is a four-digit display and will

appear as “000.0” feet, 2, or “00.00” meters with the

left-hand digit, 1, flashing. “IMP WIDTH CAL,” 7, and

either “FT,” 6, or “METERS” will also be displayed.

Touch the digit select switch, 4, to move the flashing

digit to the right. Touch the digit set switch, 5, to

increase the numerical value of the flashing digit.

For example: To set an implement working width of

12.5 feet, a display of “012.5” is required. Touch the

DIGIT SELECT switch, 4, to cause the second digit

from the left to flash. Touch the DIGIT SET switch, 5,

to change the flashing digit from “O” to “1.”

Use the DIGIT SELECT, 4, and DIGIT SET, 5,

switches to change the remaining digits until “012.5”

is displayed.

NOTE: The area measured will only be accurate if

there is no implement overlap when the tractor turns

around at the end of a run to make another pass.

Alternatively, the implement width entered into

memory may be reduced by the estimated amount of

overlap.

With the required implement width displayed, touch

the SET UP/SELECT switch, 3, to enter the

implement width into memory and change the

display to the % SLIP alarm point.

46

Setting The Slip Alarm Point (Option)
NOTE:
If the optional radar unit is not installed, the

slip alarm function will be omitted from the sequence.

The slip alarm point will appear as a two-digit display,

1, with the left-hand digit flashing. “% SLIP,” 2, and

“ALARM,” 3, will also be displayed with the word

CAL, 4.

Use the DIGIT SET, 7, and DIGIT SELECT, 6,

switches to change the value to the required setting.

If the slip alarm is not required, set the display, 1, to

“00.”

With the required slip alarm point displayed, touch

the SET UP/SELECT switch, 5, to change the lower

display to show the first Service Alert Indicator “I.”

NOTE: Slip limit control will not operate below 0.8

km/h (0.5 MPH). Slip limit control will disengage

when the 3-point linkage is raised and re-engage

when the implement is lowered into the ground.

47