SECTION 3 - LUBRICATION AND MAINTENANCE

3-30

EVERY 300 HOURS

7. Install filter and tighten until sealing ring contacts

mounting surface, then tighten an additional 3/4

to 1 full turn. DO NOT OVERTIGHTEN.

8. Remove filler cap, 1, and fill with 19 liters (5

gallons) of fresh oil of the grade and viscosity

prescribed in the “Specification” section.

9. Remove the cover from the right side “B” pillar to

get access to the main electrical distribution

panel. See “Operation 65” for details on

removing the cover.

53

10. Remove the fuel solenoid relay, 1, (second from

the bottom) from the main distribution panel. This

will prevent the engine from starting.

11. Crank the engine for 20 seconds. Wait one

minute. Repeat the procedure two more times.

IMPORTANT: Cranking the engine provides lubrica-

tion to the turbocharger and engine before starting

which will extend engine life.

12. Reinstall the fuel solenoid relay, 1, and “B” pillar

cover.

13. Run the engine at idle for 3 minutes, then stop the

engine.

14. Check drain plug and oil filter areas for leaks.
15. Wait 5 minutes to allow oil to drain into the

crankcase, then check the oil level on the

dipstick, 2. The oil level should be in the

crosshatched area, 3, Figure 53.

16. Add new oil as required until the oil level is in the

crosshatched area.

NOTE: Do not fill above the upper line of the

crosshatched area. Excessive oil will be burned off

within a short time and give a false impression of oil

consumption.

Oil Specification: API CF-4
Refer to the “Specification” section for the correct

oil viscosity.
Oil Capacity (including filter) - 21 liters (5.5 US

gallons)