SECTION 3 - LUBRICATION AND MAINTENANCE

3-59

EVERY 2400 HOURS OR 24 MONTHS (WHICHEVER OCCURS FIRST)

6. Close the shutoff valves, 1, at the filter/condition-

er, 2.

7. Remove the filter/conditioner.
8. Flush the system with a commercial coolant

system cleaner. Follow the instructions supplied

with the cleaner.

9. Drain the cleaner and let the engine cool.
IMPORTANT: Never put cold coolant in a hot engine.

The difference in temperature could cause the block

or head to crack.

10. Fill system with clean water.
11. Run engine for 10 minutes, then drain all the

water. Allow the engine to cool.

12. Close all drain plugs.
13. Coat the filter seal, 3, with coolant.
IMPORTANT: The standard replacement condition-

er filter contains conditioning additive. If the

replacement coolant is fully formulated and contains

the correct amount of conditioner, a coolant filter

without conditioner should be used. See “Part

Numbers of High Usage Items” in the specifications

section of this manual or contact your Buhler

Versatile Dealer.

14. Wipe the sealing surface of the filter manifold, 4.
15. Install the filter until the gasket contacts the

manifold. Tighten an additional 1/2 to 3/4 turn.

DO NOT OVERTIGHTEN.

16. Open the shutoff valves, 1, at the filter manifold.
17. Inspect cooling system hoses and connections

for leaks.

18. Fill the cooling system with a 50/50 blend of low

silicate antifreeze and clean soft water. Add

coolant slowly through the radiator filler neck until

the coolant is to the bottom of the filler neck.

NOTE: To avoid trapping air in the system, fill the

radiator as slowly as practicable thereby allowing

any air pockets to disperse.

102

Advertising
This manual is related to the following products: