Buhler 2180 User Manual

Page 110

Advertising
background image

SECTION 2 - OPERATION

2-64

ENGINE BLOCK HEATER

The engine block heater, 1, warms the engine

coolant to aid starting by reducing engine drag.

When used with the cold start system, the heater is

an effective starting aid in temperatures down to -29°

C (-20° F).

To operate the heater, plug the heater cord, 2, into a

suitable 115-volt circuit for at least four hours before

starting the tractor.

You can leave the heater in operation for periods

longer than four hours without damage, but

maximum starting ability is usually attained after the

coolant has been heated for four hours.

WARNING

To avoid shocks or other injuries, never use an

ungrounded or inadequate extension cord.

Always use a grounded 3-wire extension cord

with a 3-wire plug which is rated for at least a

15-ampere load, and protected by a suitable fuse

or circuit breaker.

98

OPTIONAL HYDRAULIC OIL SUMP

HEATER

The sump heater will help to keep the

hydraulic oil at a warm temperature which aids

cold weather starting. The heater is installed

in the left side of the rear axle assembly. To

operate the heater, plug the heater cord, 1,

into a suitable 115-volt circuit.

WARNING

To avoid shocks or other injuries, never use an

ungrounded or inadequate extension cord.

Always use a grounded 3-wire extension cord

with a 3-wire plug which is rated for at least a

15-ampere load, and protected by a suitable fuse

or circuit breaker.

99

Advertising
This manual is related to the following products: