Buhler 2180 User Manual

Page 269

Advertising
background image

SECTION 4 - TROUBLESHOOTING

4-7

HYDRAULIC SYSTEM

PROBLEM

POSSIBLE CAUSE

CORRECTION

Complete hydraulic system does

not operate

Low oil level

Restricted hydraulic filter

Restricted charge pump suction

screen

Blown fuse - bad relay

Malfunctioning hydraulic system

Fill system

Replace hydraulic filter

Clean screen

Replace fuses and or relay

See your authorized dealer

Hydraulic oil overheats

Oil level low or high

Oil cooler or radiator plugged

Blocked oil filter element

Flow control improperly adjusted

Hydraulic load or orbit motor not

matched to tractor

Adjust oil level

Clean oil cooler and radiator

Replace filter

Adjust flow control to lower flow

position

See your authorized dealer

Hoses will not couple

Incorrect male connectors

Replace connectors with ISO-

(1/2″) standard connectors avail-

able from your authorized dealer

Remote attachment operates too

fast or too slow

Flow control not properly adjusted Adjust flow control

Remote attachment does not

operate

No power to EHR system

Fuse Blown

Hoses not completely connected

Flow checking in couplers

Load exceed system capacity

Ensure power switch is on (raised)

position: see engagement switch

page 2--79

See your authorized dealer

Attach hoses correctly

Cycle remote switches. If problem

persists replace male couplers.

Reduce load or use correct size

cylinder

Advertising