SECTION 3 - LUBRICATION AND MAINTENANCE

3-57

EVERY 2400 HOURS OR 24 MONTHS (WHICHEVER OCCURS FIRST)

OPERATION 60

CHANGE ENGINE COOLANT AND

FILTER/CONDITIONER

The rust and corrosion inhibitors in the antifreeze and

the filter/conditioner deteriorate with use and require

replacement on a regular basis.

The tractor is equipped with a water filter with coolant

conditioner. The water filter/conditioner removes

foreign material from the cooling system, controls

rust, and conditions the coolant to prevent erosion

and cavitation in the cooling system.

See “Operation 56” for additional information on the

filter/conditioner.

WARNING

The coolant system operates under pressure

which is controlled by the radiator pressure cap.

It is dangerous to remove the pressure cap while

the system is hot. When the system has cooled,

use a thick cloth and turn the cap slowly to the

first stop and allow the pressure to escape before

fully removing the cap. Coolant should be kept

off the skin. Adhere to the precautions outlined

on the antifreeze and inhibitor containers, where

used.

CAUTION

Drain the coolant when the engine is cool.

Park the tractor on level ground and engage the park

brake and block the wheels front and rear.

To change coolant and the filter/conditioner:

1. Turn the heater control knob to the maximum

position.

2. Check that the heater shutoff valves, 1, are open.