SECTION 3 - LUBRICATION AND MAINTENANCE

3-45

EVERY 900 HOURS OR 12 MONTHS (WHICHEVER OCCURS FIRST)

OPERATION 50

CLEAN HYDRAULIC PUMP INLET SCREEN

NOTE: Perform this operation while oil is drained in

“Operation 49.”

NOTE: Clean inlet screen area before proceeding.

To clean the inlet screen:

1. Remove the three attaching bolts, 1, from the end

cover, 2.

79

2. Pull the end cover, 1, down until it is free of the

coupler, 2.

NOTE: Do not damage the O rings, 3, when

removing the end cover.

80

3. Remove the suction screen, 1, by turning it

counterclockwise.

4. Clean the sump area.
5. Clean, then inspect, suction screen and all O

rings. Replace if damaged.

6. Install the suction screen. Turn clockwise until

hand tight, then turn an additional 1/4 turn. Do not

over tighten.

7. Install the O ring, 2, on the housing and lubricate

with oil.

8. Oil the exposed O ring, 3, on the coupler.
9. Install the end cover and coupler. Do not damage

the O rings.

10. Install the attaching bolts and torque to 50 N·m

(37 ft.-lbs.).