SECTION 2 - OPERATION

2-79

The remote valve control switches have four

positions: neutral, extend, retract, and float.

Pull the switch back from the neutral position, 1, to

the “extend” (raise) position, 2. From neutral, push

forward to the “retract” (lower) position, 3. Push the

switch fully forward to the float position, 4. Float will

permit the cylinder to extend or retract allowing

equipment such as scraper blades to “float” or follow

the ground contour.

The “float” position is also used for retracting a

single-acting cylinder and for the OFF position for

hydraulic motors.

1

2

3

4

116

The extend, 1, neutral, 2, retract, 3, and float, 4,

positions are identified by symbols on the decal

behind each control switch.

NOTE: Do not hold or fasten the switch in the extend

or retract position after a remote cylinder has

reached the end of its stroke. This will overheat the

oil and may lead to failure of hydraulic and driveline

components.

117

ENGAGEMENT SWITCH

The control switches and remote valves will not

operate until the system is activated by the

electro-hydraulic engagement switch. To activate the

remote hydraulic system, depress the center button,

1, in the engagement knob, 2. Pull the knob up until

it stops, then release the center button and let go of

the knob. The electro-hydraulic system is now

operational when ever the engine running.