FUEL STORAGE

Take the following precautions to ensure that stored

fuel is kept free of dirt, water, and other

contaminants.

Store fuel in black iron tanks, not galvanized

tanks, as the zinc coating will react with the fuel

and form compounds that will contaminate the

injection pump and injectors.

Install bulk storage tanks away from direct

sunlight and angle them slightly so sediment in

the tanks will settle away from the outlet pipe.

To facilitate moisture and sediment removal,

provide a drain plug at the lowest point at the end

opposite the outlet pipe.

If fuel is not filtered from the storage tank, put a

funnel with a fine mesh screen in the fuel tank

filler neck when refueling.

Arrange fuel purchases so summer grade fuels

are not held over and used in winter.

ADDING DIESEL FUEL

1. Clean the area around the fuel cap, 1, to prevent

debris from entering the fuel tank, 2.

2. Remove the cap and place in a clean area during

refueling.

3. After filling the tank, replace and tighten the fuel

cap.

NOTE: Fuel tank capacity is 416 liters (110 US

gallons).

IMPORTANT: Replace a lost or damaged cap with a

genuine Buhler Versatile replacement cap.