2 overview of monitoring functions, Overview of monitoring functions, Monitoring functions – Lenze ECSCExxx Power supply module User Manual

Page 101

Advertising
background image

Monitoring

functions

Overview of monitoring functions

9

l

101

EDBCSXE040 EN 7.0

9.2

Overview of monitoring functions

Monitoring

Possible responses

l Lenze setting

ü Setting possible

Fault message

Description

Code

TRIP

Short−
circuit

brake TRIP

Message

Warning

Off

0011 OC1

Short circuit in the DC bus

ü

l

˘

˘

˘

0012 OC2

Earth fault in the DC bus

ü

l

˘

˘

˘

0013 OC3

Load of the DC bus during load process (from operating system V2.3)

ü

l

˘

˘

˘

0014 OC4

Short circuit/overload of brake resistor or IGBT

l

˘

˘

˘

˘

0015 OC5

Device utilisation I x t (fix 100%)

ü

l

˘

˘

˘

0016 OC6

Overload of internal brake resistor

C0579

l

˘

˘

ü

0020 OU

Overvoltage in the DC bus (C0173)

ü

l

˘

˘

˘

1031
2031

LP0

Mains voltage outside the operating range

˘

˘

l

ü

˘

0032
1032
2032

LP1

Mains phase failure (from operating system V2.0)

l

C0599 < 65535: LP1−TRIP

l

C0599 = 65535: LP1 warning/LP1 message

C0599

ü

l

ь

ь

˘

0050 OH

Device heatsink temperature > 90

C

ü

l

˘

˘

˘

0051 OH1

Internal device temperature > 90

C

ü

l

˘

˘

˘

0053 OH3

Overload of external brake resistor

l

˘

˘

˘

˘

0061 CE0

Communication error on the automation interface (AIF)

C0126

ü

˘

˘

˘

l

0062 CE1

Communication error at the process data input object CAN1_IN in cyclic operation
(sync−controlled)

l

The monitoring time can be set via C0357/1.

ь

ь

˘

˘

l

0063 CE2

Communication error at the process data input object CAN2_IN in
event−controlled/cyclic operation without sync

l

The monitoring time can be set via C0357/1.

ь

ь

˘

˘

l

0064 CE3

Communication error at the process data input object CAN3_IN in
event−controlled/cyclic operation without sync

l

The monitoring time can be set via C0357/1.

ь

ь

˘

˘

l

0065 CE4

Bus−off status of the system bus (CAN)
(too many faulty telegrams or toggle bit errors)

C0595

ü

l

˘

˘

ü

0070 U15

Undervoltage of external low−voltage supply

l

˘

˘

˘

˘

0071 CCr

System failure

ü

l

˘

˘

˘

0072 PR1

Checksum error in parameter set 1

ü

l

˘

˘

˘

0079 PR5

Internal fault (EEPROM)

ü

l

˘

˘

˘

Advertising