Appendix

Codes

12

l

142

EDBCSXE040 EN 7.0

Parameter

C0444

Designation

Status of digital outputs

Data type: UNSIGNED_16

Index: 2413

dec

= 5E43

hex

Bit coded display of the digital output status

Display range

(min. value | unit | max. value)

0x0000

0xFFFF

Bits

(read only)

Information

Bit 0 Trigger signal − +UG−relay

Bit 1 Trigger signal − −UG−relay

Bit 2 Trigger signal − IGBT

Bit 3 Trigger signal − thyristor

(LOW−active)

Bit 4 Internal signal ready for operation

(RDY)

Bit 4 = 1 (TRUE):
DC bus charged AND controller enable active (X6/DI2 =
HIGH or control word Ctrl1.Bit03 = 1)

Bit 5 Status of green LED (LOW−active)

Bit 6 Status of red LED (LOW−active)

Bit 7 Trigger signal − heatsink fan

(LOW−active)

Bit 8 IGBT gate driver reset (LOW−active)

Bit 9

Not assigned

...

Bit 15

Parameter

C0468

Designation

Function of power supply enable (X6/DI1)

Data type: INTEGER_32

Index: 24107

dec

= 5E2B

hex

Setting of power supply enable via terminal X6/DI1
Note: The parameters can only be changed if the controller is inhibited.

^ 69
Selection list

(Lenze setting printed in bold)

Information

0 Mains disconnection (slow

discharge)

1 Mains disconnection and

TRIP−RESET

2 Mains disconnection and quick

discharge (short−circuit braking)

4 Mains disconnection, quick

discharge (short−circuit braking),
and TRIP−RESET

Parameter

C0469

Designation

Function of "STOP" keypad key for ECSxE

Data type: INTEGER_32

Index: 24106

dec

= 5E2A

hex

Setting of the "STOP" keypad key function of the ECSxE power supply module
Note: The parameters can only be changed if the controller is inhibited.

Selection list

(Lenze setting printed in bold)

Information

0 No function

1 Mains disconnection (slow

discharge)

2 Quick discharge (short−circuit

braking)

Advertising