Fault messages
Causes and remedies

11

l

122

EDBCSXE040 EN 7.0

11.2

Fault messages

11.2.1

Causes and remedies

I

Tip!

When the fault messages are retrieved via the system bus (CAN) they are
displayed as a number (see column fault number ˘number" in the following
table).

Fault message

Description

Cause

Remedy

No.

Display

−−−

−−−

No fault

˘

˘

0011 OC1

Short circuit in the DC bus

Short circuit

l

Find cause of short−circuit

l

Check DC bus wiring

Charging current limitation of
the axis module is active.

Do not use charging current
limitation

0012 OC2

Earth fault in the DC bus

One of the DC bus cables has
earth contact

Check DC bus wiring

DC−bus capacity is too low

Increase capacity

0013 OC3

Load of the DC bus during
charging
(from software version 2.3)

l

Power consumption of the DC
bus while charging

l

Max. charging current too
low (C0022)

l

Check system control/wiring

l

Increase max. charging
current (C0022)

0014 OC4

Short circuit/overload of brake
resistor or IGBT

l

Brake IGBT defective

l

Brake resistor has low
resistance

l

No brake resistor connected

l

Check brake resistor

l

Replace device

0015 OC5

I x t overload

l

Frequent and too long
acceleration with overcurrent

l

Continuous overload with
I

mains

> 1.05 x I

r

Check dimensioning

0016 OC6

Overload of internal brake
resistor

l

Brake resistor thermally
overloaded, caused e.g. by
frequent or too long braking
processes

l

OC6 monitoring activated
while an external brake
resistor is used

l

Use external brake resistor

l

Deactivate OC6 monitoring
when an external brake
resistor is used (C0579 = 3)

0020 OU

Overvoltage in the DC bus

Excessive braking energy
(DC−bus voltage higher than
880 V)

l

Use braking unit or
regenerative module

l

Check brake resistor
dimensioning

1031
2031

LP0

Mains voltage beyond the
operating range

Mains voltage beyond range
defined under C0173

l

Check mains voltage

l

Adapt C0173