Appendix – Lenze ECSCExxx Power supply module User Manual

Page 159

Advertising
background image

Appendix

General information about the system bus (CAN)

Parameter data transfer

12

l

159

EDBCSXE040 EN 7.0

12.3.4.1

User data

Structure of the parameter data telegram

User data (up to 8 bytes)

1. byte

2. byte

3. byte

4. byte

5. byte

6. byte

7. byte

8. byte

Command

Index

Low byte

Index

High byte

Subindex

Data 1

Data 2

Data 3

Data 4

Low word

High word

Low byte

High byte

Low byte

High byte

Display

)

Note!

The user data is shown in motorola format.
Examples for parameter data transfer can be found from

^ 162.

Command

The command contains the services for writing and reading the parameters and
information on the length of the user data:

Command

Bit 7
MSB

Bit6

Bit5

Bit4

Bit3

Bit 2

Bit 1

Bit 0

LSB

Command specifier (cs)

toggle (t)

Length

e

E

Write request

0

0

1

0

00 = 4 bytes
01 = 3 bytes
10 = 2 bytes

11 = 1 byte

1

1

Write response

0

1

1

0

0

0

Read request

0

1

0

0

0

0

Read response

0

1

0

0

1

1

Error response

1

0

0

0

0

0

0

0

I

Tip!

Further commands are defined in the CANopen specification DS301, V4.02
(e.g. segmented transfer).