7 executing a reset node, Executing a reset node, Configuring system bus (can) – Lenze ECSCExxx Power supply module User Manual

Page 94

Advertising
background image

Configuring system bus (CAN)

Executing a reset node

8

l

94

EDBCSXE040 EN 7.0

8.7

Executing a reset node

The following changes will only be valid after a reset node:

ƒ

Changes of the CAN node addresses and baud rates (

^

82)

ƒ

Changes of the addresses of process data objects (COB−IDs)
– General addressing (

^

164)

– Individual addressing (

^

86)

ƒ

Change of the master/slave boot up configuration (

^

88)

A reset node can be made by:

ƒ

Switching on again the low−voltage supply

ƒ

Reset node via the bus system (by the network management (NMT))

ƒ

Reset node with C0358 = 1 by means of keypad XT
– If the reset node is executed via GDC, the communication will be interrupted as a

matter of principle. Thus, it is required to log in again manually or to research the
devices connected to the bus.

Parameter

C0358

Designation

CAN reset node

Data type: INTEGER_32

Index: 24217

dec

= 5E99

hex

Make a reset node for the CAN bus node.

^ 94
Selection list

(Lenze setting printed in bold)

Information

0 No function

1 CAN reset

Advertising