5 operation with external brake resistor, Operation with external brake resistor, Commissioning – Lenze ECSCExxx Power supply module User Manual

Page 71: Stop

Advertising
background image

Commissioning

Operation with external brake resistor

6

l

71

EDBCSXE040 EN 7.0

6.5

Operation with external brake resistor

When an external brake resistor is used, monitoring of the internal brake resistor (OC6)
must be deactivated with C0579 = 3.

ƒ

C0579 can be found in the GDC parameter menu (

^ 75) under Short setup and

Monitoring.

(

Stop!

The device can be destroyed if the monitoring is deactivated while the internal
brake resistor is used.

Parameter

C0579

Designation

Response − monitoring of internal brake resistor (OC6)

Data type: INTEGER_32

Index: 23996

dec

= 5DBC

hex

Monitoring response of the internal brake resistor (fault message OC6)

^ 106
Selection list

(Lenze setting printed in bold)

Information

0 TRIP

3 No response