4 configuring power supply enable input, Configuring power supply enable input, Commissioning – Lenze ECSCExxx Power supply module User Manual

Page 69

Advertising
background image

Commissioning

Configuring power supply enable input

6

l

69

EDBCSXE040 EN 7.0

6.4

Configuring power supply enable input

A HIGH level at the power supply enable input X6/DI1 enables the charging of the DC bus.

Even if the control is carried out via the system bus (CAN), the input must be set to HIGH
level to charge the DC bus.

The reaction of the power supply module to a low level or falling edge at X6/DI1 can be set
under C0468.

ƒ

C0468 can be found in the GDC parameter menu (

^ 75) under Digital I/O.

Parameter

C0468

Designation

Function of power supply enable (X6/DI1)

Data type: INTEGER_32

Index: 24107

dec

= 5E2B

hex

Setting of power supply enable via terminal X6/DI1
Note: The parameters can only be changed if the controller is inhibited.

^ 69
Selection list

(Lenze setting printed in bold)

Information

0 Mains disconnection (slow

discharge)

1 Mains disconnection and

TRIP−RESET

2 Mains disconnection and quick

discharge (short−circuit braking)

4 Mains disconnection, quick

discharge (short−circuit braking),
and TRIP−RESET

)

Note!

Mains voltage dips can be reduced by decreasing the max. charging current
limit (C0022).

ƒ

C0022 can be found in the GDC parameter menu (

^ 75) under Short setup.

Parameter

C0022

Designation

Max. charging current after power supply enable

Data type: INTEGER_32

Index: 24553

dec

= 5FE9

hex

Setting of the maximum charging current after power supply enable

Setting range

(min. value | unit | max. value)

Lenze setting

2.0

A

25.0

ECSxE040: 32.0

(from firmware V4.0)

16.0 A