Commissioning, Stop – Lenze ECSCExxx Power supply module User Manual

Page 68

Advertising
background image

Commissioning

Setting chopper operation and short−circuit braking

6

l

68

EDBCSXE040 EN 7.0

6.3

Setting chopper operation and short−circuit braking

The "short−circuit braking" function serves to rapidly discharge the DC bus via the brake
resistor. For this, the brake chopper IGBT is switched on permanently. The low−voltage
supply of the power supply module must be ensured for this purpose.

(

Stop!

Pay attention to the kinetic energy of permanent−magnet synchronous motors
during short−circuit braking!
Observe when short−circuit braking is deactivated:

ƒ

Rapid discharge of the DC bus via the brake resistor is not possible.

ƒ

For rapid discharge of the DC bus parameterise the charge relay function of
the connected ECS axis modules with C0175 = 3.

ƒ

For the earth−fault test the DC bus is discharged via the brake resistor after
switching on the low−voltage supply, independently of the settings.

ƒ

The discharging time depends on the entire DC bus circuit.

Observe when brake chopper IGBT is switched off:
During operation in generator mode

ƒ

overvoltage can occur in the DC bus.

ƒ

energy cannot be discharged from the DC bus.

ƒ

This function is carried out automatically with most error messages (

99) but it

can also be requested via the master control system or manually.

ƒ

As the DC bus must be safely disconnected from the mains for short−circuit braking,
the brake chopper IGBT is switched on with a delay of approx. 150 ms after the
short−circuit braking request.

ƒ

The power supply enable input X6/DI1 can be configured in such a way that
short−circuit braking is triggered with a LOW level (

69).

ƒ

The control bit 2 (STE_KSB) can be set by the control system when bus control is
used (

95).

ƒ

In the case of manual operation (C0001 = 1), the STOP key of the keypad XT can also
be configured to short−circuit braking via C0469.

The short−circuit braking function can be activated in the GDC parameter menu (

^ 75)

under Short setup via C0127.

Parameter

C0127

Designation

Function of integrated brake transistor

Data type: INTEGER_32

Index: 24448

dec

= 5F80

hex

Activation of brake chopper IGBT/fast discharge function (short−circuit braking)

^ 68
Selection list

(Lenze setting printed in bold)

Information

0 Brake chopper and short−circuit

braking

1 Only brake chopper

2 Only fast discharge function

(short−circuit braking)

4 Without function

Advertising
This manual is related to the following products: