Appendix, Codes – Lenze ECSCExxx Power supply module User Manual

Page 128

Advertising
background image

Appendix

Codes

12

l

128

EDBCSXE040 EN 7.0

Parameter

C0043

Designation

Reset fault message

Data type: INTEGER_32

Index: 24532

dec

= 5FD4

hex

Reset active fault message (TRIP−RESET)

^ 125
Selection list

(Lenze setting printed in bold)

Information

0 TRIP−RESET / no fault

1 Fault active

Parameter

C0050

Designation

Mains voltage (V

rms

) between phases L1−L2

Data type: INTEGER_32

Index: 24525

dec

= 5FCD

hex

Display of the mains voltage (V

rms

) between phases L1 and L2

Display range

(min. value | unit | max. value)

−16383

V

16383

Parameter

C0051

Designation

Mains voltage (V

rms

) between phases L2−L3

Data type: INTEGER_32

Index: 24524

dec

= 5FCC

hex

Display of the mains voltage (V

rms

) between phases L2 and L3

Display range

(min. value | unit | max. value)

−16383

V

16383

Parameter

C0053

Designation

DC−bus voltage (U

G

)

Data type: INTEGER_32

Index: 24522

dec

= 5FCA

hex

Display of the DC−bus voltage (U

G

)

Display range

(min. value | unit | max. value)

−32767

V

32767

Parameter

C0054

Designation

Mains current (r.m.s. value)

Data type: INTEGER_32

Index: 24521

dec

= 5FC9

hex

Display of the mains current (r.m.s. value)

Display range

(min. value | unit | max. value)

−1638.3

A

1638.3

Parameter

C0055

Designation

Voltage across the brake resistor

Data type: INTEGER_32

Index: 24520

dec

= 5FC8

hex

Display of the voltage across the brake resistor

Display range

(min. value | unit | max. value)

−32767

V

32767

Parameter

C0057

Designation

Mains frequency

Data type: INTEGER_32

Index: 24518

dec

= 5FC6

hex

Display of the mains frequency

Display range

(min. value | unit | max. value)

−3276.7

Hz

3276.7

Advertising