Commissioning

Configuring power supply enable input

6

l

70

EDBCSXE040 EN 7.0

STOP key of the keypad XT

The STOP key only functions if controlled via digital inputs (C0001 = 1).

ƒ

The function of the STOP key can be set in the GDC parameter menu (

^ 75) under

Keypad configuration via C0469.

(

Stop!

Do not change the function of the STOP key if the STOP function has
previously been activated by pressing the STOP key. The device cannot be
restarted in this case.

Parameter

C0469

Designation

Function of "STOP" keypad key for ECSxE

Data type: INTEGER_32

Index: 24106

dec

= 5E2A

hex

Setting of the "STOP" keypad key function of the ECSxE power supply module
Note: The parameters can only be changed if the controller is inhibited.

Selection list

(Lenze setting printed in bold)

Information

0 No function

1 Mains disconnection (slow

discharge)

2 Quick discharge (short−circuit

braking)