Configuring system bus (CAN)

Node guarding

8

l

93

EDBCSXE040 EN 7.0

Parameter

C0383

Designation

CAN Node Guarding: "Node Life Time Factor"

Data type: INTEGER_32

Index: 24192

dec

= 5E80

hex

Factor for monitoring time "Node Life Time"

l

Node Life Time = C0383 x C0382

l

Only relevant if C0352 = 2.

^ 92
Setting range

(min. value | unit | max. value)

Lenze setting

0

255 0

Parameter

C0384

Designation

Response − CAN node guarding

Data type: INTEGER_32

Index: 24191

dec

= 5E7F

hex

Response to a "Life Guarding Event"if no node guarding telegram has been received during "Node Life Time"
(C0382 x C0383).

l

When C0382 = 0 or C0383 = 0, the monitoring function is not active (no node guarding fault message is
enabled).

l

Only relevant if C0352 = 2.

^ 92
Selection list

(Lenze setting printed in bold)

Information

0 TRIP

1 Message

2 Warning

3 Off