Appendix – Lenze ECSCExxx Power supply module User Manual

Page 163

Advertising
background image

Appendix

General information about the system bus (CAN)

Parameter data transfer

12

l

163

EDBCSXE040 EN 7.0

Writing parameters

The acceleration time C0012 (parameter set 1) of the controller with the node address 1 is
to be changed to 20 seconds via the SDO1 (parameter data channel 1).

ƒ

Identifier calculation

Identifier from SDO1 to controller

Calculation

1536 + node address

1536 + 1 = 1537

ƒ

Command "Write Request" (transmit parameter to drive)

Command

Value [hex]

Write request

0x23

ƒ

Index calculation

Index

Calculation

24575 − code number

24575 − 12 = 24563 = 0x5FF3

ƒ

Subindex: 0

ƒ

Calculation of the acceleration time

Data 1 ... 4

Calculation

Value for acceleration time

20 s

ú 10000 = 200000

= 0x00030D40

ƒ

Telegram to controller

Identifier

User data

Command

Index

LOW byte

Index

HIGH byte

Subindex

Data 1

Data 2

Data 3

Data 4

1537

0x23

0xF3

0x5F

0x00

0x40

0x0D

0x03

0x00

ƒ

Telegram from controller if executed faultlessly

Identifier

User data

Command

Index

LOW byte

Index

HIGH byte

Subindex

Data 1

Data 2

Data 3

Data 4

1409

0x60

0xF3

0x5F

0x00

0x00

0x00

0x00

0x00

– Command:

"Write Response" (response of the controller (acknowledgement)) = 0x60

– Identifier:

SDO1 from controller (= 1408) + node address (= 1) = 1409