8 configuring system bus (can), Configuring system bus (can), Configuring system bus (can) 8 – Lenze ECSCExxx Power supply module User Manual

Page 81: 8configuring system bus (can)

Advertising
background image

Configuring system bus (CAN)

8

l

81

EDBCSXE040 EN 7.0

8

Configuring system bus (CAN)

The drive system can be adapted to your application by configuring the power supply
module. These interfaces can be used to configure the power supply module:

ƒ

X1 ˘ AIF (automation interface)
– For the connection of the keypad XT or communication modules (

^ 167) which

serves to access the codes.

ƒ

X4 ˘ System bus interface (CAN)
– PC interface/HMI for parameter setting and diagnostics (e.g. with the Lenze

parameter setting and operating program "Global Drive Control")
or

– Interface to a decentralised I/O system

The codes for configuring the system bus (CAN) can be found in the GDC parameter menu
(

^ 75) under system bus (CAN).

X4

4

5

X4

X14

X4

X14

X4

X14

Systembus (CAN)

MotionBus (CAN)

Y Z

y

z

T V
S U

d

A

B

b

c

p

SHPRG

Para

Code

Menu

0050

00

50.00_Hz

M C T R L- N O U T

X1

X1

X4

X14

X1

X1

0

1

3

X1

2

ECSXA028

Fig. 8−1

Example: Wiring of the MotionBus (CAN) and system bus (CAN)
0

Keypad XT or another communication module

1

PC/laptop or HMI

2

Decentralised I/O system

3

Higher−level host system / MotionBus control

4

ECSxE... power supply module

5

ECSxS/P/M/A... axis module

I

Tip!

More detailed information on the CAN bus can be found in the appendix of
this documentation (

147).