9 assignment of status words, Assignment of status words, Configuring system bus (can) – Lenze ECSCExxx Power supply module User Manual

Page 96

Advertising
background image

Configuring system bus (CAN)

Assignment of status words

8

l

96

EDBCSXE040 EN 7.0

8.9

Assignment of status words

Status word 1 (display in C0131)

Byte

Bit

Name

Meaning

LOW

0

STA1_BTB

0:
1:

Power supply module not ready for operation
Status message: ready for operation

1

STA1_WARNUNG

0:
1:

No warning active
At least one warning active

2

STA1_MELDUNG

0:
1:

No message active
At least one message active

3

STA1_TRIP

0:
1:

No TRIP active
At least one TRIP active

4

STA1_KSB_FAIL

0:
1:

OK
No short−circuit braking possible because DC bus charged
externally.

5

STA1_KSB_AKTIV

0:
1:

Normal operation
Short−circuit braking active

6

STA1_K1_EIN

0:
1:

−UG relay open
−UG relay closed (switched−on)

7

STA1_K2_EIN

0:
1:

+UG relay open
+UG relay closed (switched−on)

HIGH

8

Reserved

...

10
11

STA1_DI1

0:
1:

Terminal mains enable (x6/DI1) LOW
Terminal mains enable (x6/DI1) HIGH

12

STA1_DI2

0:
1:

Terminal controller enable (X6/DI2) LOW
Terminal controller enable (X6/DI2) HIGH

13

STA1_TOGGLE

Feedback of received toggle bit
(as of operating software V2.3)

14

Free

15

Status word 2 (display under C0132)

The current fault number is transferred in status word 2 (

122).