9 monitoring functions, Monitoring functions, 99) but it – Lenze ECSCExxx Power supply module User Manual

Page 99: Monitoring functions 9, 9monitoring functions

Advertising
background image

Monitoring functions

9

l

99

EDBCSXE040 EN 7.0

9

Monitoring functions

Different monitoring functions (

101) protect the drive system from impermissible

operating conditions.

If a monitoring function responds,

ƒ

the set fault response is triggered to protect the drive and

ƒ

the fault message is entered position 1 in the fault history buffer (C0168/x, in case
of ECSxP: C4168/x) (

120).

In the fault history buffer (C0168/x), fault messages are saved in codes as 4−digit numbers.
The first digit describes the type of fault response. The last three digits correspond to the
fault number.

No. of the fault message

Type of response

0xxx

TRIP

1xxx

Message

2xxx

Warning

3xxx

FAIL−QSP (only for ECSxS/P/M/A axis modules)

Example: C0168/1 = 2061

ƒ

x061:
The current fault (subcode 1 of C0168) is a communication error (fault message
"CE0"/no. "x061") between the AIF module and the ECS axis module.

ƒ

2xxx:
The fault response is a warning.

Advertising