Configuring system bus (CAN)

Setting the CAN node address and baud rate

Settings via DIP switch

8

l

83

EDBCSXE040 EN 7.0

Node address setting

The node address is set with the switches 2 ... 7 of the DIP switch. The switches are
assigned to certain valencies. The sum of the valencies make the node address to be set
(see example).

Switch

Valency

Example

Switching status

Node address

ON

OFF

ON

1

6

2

7

4

3

8

5

91

0

S1

No function

S2

32

ON

32 + 16 + 8 = 56

S3

16

ON

S4

8

ON

S5

4

OFF

S6

2

OFF

S7

1

OFF

Baud rate setting

)

Note!

The baud rate must be set identically for all CAN nodes.

Switch

Baud rate [kbit/s]

1000

500

250

125

50

ON

OFF

ON

1

6

2

7

4

3

8

5

91

0

8

ON

OFF

OFF

OFF

OFF

9

OFF

OFF

OFF

ON

ON

10

OFF

OFF

ON

OFF

ON