Codes

12

l

130

EDBCSXE040 EN 7.0

Parameter

C0125

Designation

LECOM baud rate (AIF)

Data type: INTEGER_32

Index: 24450

dec

= 5F82

hex

Baud rate for operation via AIF interface

Selection list

(Lenze setting printed in bold)

Information

0 9600 bits/s

1 4800 bits/s

2 2400 bits/s

3 1200 bits/s

4 19200 bits/s

Parameter

C0126

Designation

Response of AIF communication monitoring (CE0)

Data type: UNSIGNED_32

Index: 24449

dec

= 5F81

hex

Response in the case of a communication error on the AIF interface (CE0 fault message)

Selection list

(Lenze setting printed in bold)

Information

0 TRIP

3 No response

Parameter

C0127

Designation

Function of integrated brake transistor

Data type: INTEGER_32

Index: 24448

dec

= 5F80

hex

Activation of brake chopper IGBT/fast discharge function (short−circuit braking)

^ 68
Selection list

(Lenze setting printed in bold)

Information

0 Brake chopper and short−circuit

braking

1 Only brake chopper

2 Only fast discharge function

(short−circuit braking)

4 Without function

Parameter

C0130

Designation

Control word "CTRL1" to power supply module

Data type: UNSIGNED_16

Index: 24445

dec

= 5F7D

hex

Bit coded display of control word "CTRL1" to the power supply module

^ 95
Display range

(min. value | unit | max. value)

0x0000

0xFFFF

Bits

(read only)

Information

Bit 0 Toggle bit

Bit 1 TRIP−RESET (low active)

Bit 2 Fast discharge (short−circuit

braking)

Bit 3 Central controller enable (for the

axis modules via output X6/DO1)

Bit 4

Not assigned

...

Bit 7

Bit 8

Reserved

...

Bit 10

Bit 11

Not assigned

...

Bit 15