11 troubleshooting and fault elimination, 1 fault analysis, 1 fault analysis via the led display – Lenze ECSCExxx Power supply module User Manual

Page 119: 2 fault analysis with keypad xt emz9371bc, Troubleshooting and fault elimination, Fault analysis via the led display, Fault analysis with keypad xt emz9371bc

Advertising
background image

Troubleshooting and fault elimination

Fault analysis

Fault analysis via the LED display

11

l

119

EDBCSXE040 EN 7.0

11

Troubleshooting and fault elimination

Failures can be quickly detected and classified by means of display elements or status
messages via the MotionBus (CAN).

Display elements and status messages provide a rough classification of the trouble.

The chapter "11.2 Fault messages" (

122)contains notes on causes and deletion of

faults.

11.1

Fault analysis

11.1.1

Fault analysis via the LED display

LED

Operating status

Check

Red

Green

Off

On

Module enabled, no fault

Off

Blinking

Module inhibited (CINH), switch−on inhibit

C0183

Blinking, 1 Hz

Off

Error (TRIP) / error short−circuit braking (short−circuit
braking TRIP)

C0168/1

Blinking, 3 Hz

Off

Message

C0183, C0168/1

Blinking, 1 Hz

Blinking

Warning with inhibited module

C0183, C0168/1

Blinking, 1 Hz

On

Warning with enabled module

11.1.2

Fault analysis with keypad XT EMZ9371BC

The status messages in the display give information on the device state.

Display

Device state

Check

RDY

Ready for operation, inhibit can be set

C0183, C0168/1

IMP

Power stage inhibited

C0183, C0168/1

Imax

Maximum current reached

Fail

Fault caused by TRIP, short−circuit braking TRIP, message or
warning

C0183, C0168/1

Advertising
This manual is related to the following products: