Electrical installation

Power terminals
Connection of an ECSxK... capacitor module (optional)

5

l

50

EDBCSXE040 EN 7.0

5.3.5

Connection of an ECSxK... capacitor module (optional)

The ECS capacitor modules support the DC−bus voltage for the drive system. These
capacitor module types are available:

ƒ

ECSxK001 (705

mF, ±20 %)

ƒ

ECSxK002 (1410

mF, ±20 %)

x

Design/mounting technique:

E = standard installation

C = Cold−plate technique

D = push−through technique

,

Documentation of the ECSxK capacitor module

Observe the enclosed notes.

L3

N

L1

L2

F4

K1

ECSxK...

K1

K1

L1

L2

L3

ECSxE...

PE

X21

+UG

+UG

+UG

+UG

+UG

-UG

-UG

-UG

-UG

-UG

PE

PE

PE

PE

PE

X22

X23

Off

On

+UG

BR1

X26

BR0

X23

T1

T2

X6

DI1

DI2

DO1

D24

+24V

GND

GND

24 V DC

+

-

2

1

0

M

3~

R

J

2

6

U

V

W PE

X24

BD1 BD2

X25

X7

+

"

"

"

"

F1...F3

Z1

"
"

"

"

ECSxS/P/M/A...

ECSXX004

Fig. 5−7

Wiring of capacitor module ECSxK...

"

HF−shield termination by large−surface connection to functional earth (see Mounting
Instructions for ECSZS000X0B shield mounting kit)

Twisted cables

K1

Mains contactor

F1 ... F4 Fuse
Z1

Mains choke / mains filter, optional

0

Contactor relay

1

System cable ˘ feedback

2

Terminal X6/SI1 of the connected axis modules (controller enable/inhibit)