Troubleshooting and fault elimination

Fault messages

Causes and remedies

11

l

123

EDBCSXE040 EN 7.0

Remedy

Cause

Description

Fault message

Remedy

Cause

Description

Display

No.

0032
1032
2032

LP1

Mains phase failure
(as of operating system V2.0)

l

No mains phase

l

Mains not sinusoidal

l

Voltage dips ("unstable
mains supply")

l

Check mains voltage

In the case of voltage dips:

l

Reduce charging current
(C0022)

l

For ECS axis modules, set
charge relay function
C0175 = 3.

0050 OH

Heatsink temperature > 90

C

Ambient temperature
T

u

> +40 C or > +50 C

l

Allow power supply module
to cool and ensure better
ventilation

l

Check ambient temperature
in the control cabinet

Heatsink very dirty

Clean heatsink

Incorrect mounting position

Change mounting position

0051 OH1

Internal device temperature
> 90

C

Ambient temperature
T

u

> +40 C or > +50 C

l

Allow power supply module
to cool and ensure better
ventilation

l

Check ambient temperature
in the control cabinet

Incorrect mounting position

Change mounting position

0053 OH3

Overload of external brake
resistor

External brake resistor too hot
by impermissibly high currents
or frequent and too long braking
processes

Check dimensioning

l

No PTC/temperature contact
connected

l

No jumper

Correct wiring

0061 CE0

Communication error on the
automation interface (AIF)

Faulty transfer of control
commands via the automation
interface (AIF).

l

Plug the communication
module/XT keypad firmly
(screw down, if necessary)

l

Switch off monitoring
(C0126 = 3)

0062 CE1

Communication error at the
process data input object
CAN1_IN in cyclic operation
(sync−controlled)

l

CAN1_IN object receives
faulty data

l

Communication is
interrupted

l

Check cable at X4

l

Check transmitter

l

Increase monitoring time
under C0357/1, if necessary

0063 CE2

Communication error at the
process data input object
CAN2_IN in
event−controlled/cyclic
operation without sync

l

CAN2_IN object receives
faulty data

l

Communication is
interrupted

l

Check cable at X4

l

Check transmitter

l

Increase monitoring time in
C0357/2, if necessary

0064 CE3

Communication error at the
process data input object
CAN3_IN in
event−controlled/cyclic
operation without sync

l

CAN3_IN object receives
faulty data

l

Communication is
interrupted

l

Check cable at X4

l

Check transmitter

l

Increase monitoring time in
C0357/3, if necessary

0065 CE4

Bus−off status of the system bus
(CAN)

Power supply module has
received too many faulty
telegrams

l

Check wiring: bus
termination available?

l

Check shield connection of
the cables

l

Check PE connection

l

Check bus load, reduce baud
rate if necessary (observe
cable length)

Toggle bit error

Transmitter does not change
toggle bit

Check transmitter

Advertising