Appendix

Codes

12

l

138

EDBCSXE040 EN 7.0

Parameter

C0356

Name

CAN time settings

Data type: INTEGER_32

Index: 24219

dec

= 5E9B

hex

Setting of the ...

l

Boot−up time

l

Cycle time

l

Activation delay

^ 90
Setting range

(min. value | unit | max. value)

0

ms

65000

Subcodes

Lenze setting

Information

C0356/1

3000 ms

CAN boot−up time

l

Delay time after mains connection for the
initialisation by the master.

l

Only valid if C0352 = 1 (master).

C0356/2

0 ms

Cycle time for CAN2_OUT

l

Diagnostics PDO C0390 (

^ 98)

C0356/3

0 ms

Cycle time for CAN3_OUT

l

Factor to task time for process data telegram
transmission.

l

0 ms = event−controlled data transmission (the
output data will only be transmitted if a value
changes in the output object)

C0356/4

20 ms

Delay time for initial transmission of the process data
object CAN3_OUT after the CAN bus changes to
"Operational"

Parameter

C0357

Designation

CAN_IN monitoring times (CE1 ... CE3)

Data type: INTEGER_32

Index: 24218

dec

= 5E9A

hex

Monitoring times for process data input objects

l

If no telegram arrives within the time set, CE1 ... CE3−TRIP is enabled.

l

Setting "0 ms" = monitoring is switched off

^ 108
Setting range

(min. value | unit | max. value)

0

ms

65000

Subcodes

Lenze setting

Information

C0356/1

0 ms

CAN1_IN monitoring time CE1

(cyclic operation (sync−controlled))

C0356/2

0 ms

CAN2_IN monitoring time CE2

(reserved)

C0356/3

0 ms

CAN3_IN monitoring time CE3

(event−controlled/cyclic operation without sync)

Parameter

C0358

Designation

CAN reset node

Data type: INTEGER_32

Index: 24217

dec

= 5E99

hex

Make a reset node for the CAN bus node.

^ 94
Selection list

(Lenze setting printed in bold)

Information

0 No function

1 CAN reset