Appendix, Codes – Lenze ECSCExxx Power supply module User Manual

Page 143

Advertising
background image

Appendix

Codes

12

l

143

EDBCSXE040 EN 7.0

Parameter

C0579

Designation

Response − monitoring of internal brake resistor (OC6)

Data type: INTEGER_32

Index: 23996

dec

= 5DBC

hex

Monitoring response of the internal brake resistor (fault message OC6)

^ 106
Selection list

(Lenze setting printed in bold)

Information

0 TRIP

3 No response

Parameter

C0595

Designation

Response − bus−off/toggle bit monitoring (CE4)

Data type: INTEGER_32

Index: 23980

dec

= 5DAC

hex

Bus−off/toggle bit monitoring response of the CAN bus (fault message CE4)

^ 108
Selection list

(Lenze setting printed in bold)

Information

0 TRIP

3 No response

Parameter

C0599

Designation

Delay time − system disturbance (LP1)

Data type: INTEGER_32

Index: 23976

dec

= 5DA8

hex

If an LP1 warning or LP1 message is active for the set time, an LP1−TRIP is enabled.

l

Value < 65535 ms: LP1−TRIP

l

Value = 65535 ms: LP1 warning/LP1 message

^ 103
Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

65535 65535 ms

Parameter

C0866

Designation

Process data input words CAN1_IN

Data type: UNSIGNED_16

Index: 23709

dec

= 5C9D

hex

If the system bus (CAN) is in the "Operational" state, you can check the contents of the data words received via
CAN1_IN via C0866 (subcodes 1 and 2).

l

The value is bit coded.

Display range

(min. value | unit | max. value)

0x0000

0xFFFF

Subcodes

Information

C0866/1

CAN1_IN.W0 (word 1, control word "Ctrl1")

C0866/2

CAN1_IN.W1 (word 2)

Parameter

C0868

Designation

Process data output words CAN1_OUT

Data type: UNSIGNED_16

Index: 23707

dec

= 5C9B

hex

If the system bus (CAN) is in the "Operational" state, you can check the contents of the data words sent via
CAN1_OUT via C0868 (subcodes 1 and 2).

l

The value is bit coded.

Display range

(min. value | unit | max. value)

0x0000

0xFFFF

Subcodes

Information

C0868/1

CAN1_OUT.W0 (word 1, status word 1 "Stat1")

C0868/2

CAN1_OUT.W1 (word 2, status word 2 "Stat2")